PhD Scientific Days 2020

Budapest, 31 August-1 September 2020

Health Sciences Posters

Test Method to Investigate the Reliability of Wall-Mounted Handrub Dispensers

Előadó neve

Bansaghi, Szava

Előadó munkahelye

Semmelweis University, School of PhD studies, Budapest, Hungary

Előadó telefonszáma

+36205262085

Előadó e-mail címe

bszava@gmail.com

Az előadás címe

Test Method to Investigate the Reliability of Wall-Mounted Handrub Dispensers

Szerző(k) neve és munkahelye

Szava Bansaghi1, Nora Balazsi2, Akos Lehotsky3, Istvan Barcs4, Tamas Haidegger5
1 School of PhD studies, Semmelweis University, Budapest, Hungary
2 Korányi National Institute of Pulmonology, Budapest, Hungary
3 National Institute of Oncology, Budapest, Hungary
4 Department of Epidemiology, Semmelweis University, Budapest, Hungary
5 University Research and Innovation Center, Obuda University, Budapest, Hungary

Szekció

Health Sciences Posters

Language of the presentation

Hungarian

Section, first choice

Health Sciences

Section, second choice

Clinical Medicine

Összefoglaló szövege

Hand hygiene with alcohol-based handrub is one of the most efficient tools in fighting healthcare-associated infections. The applied volume of handrub is critical for efficacy. In clinical settings, handrub is usually provided by the means of wall-mounted dispensers. Our previous study found that the dispensed amount can decrease dramatically if dispensers are not in use for a few hours.
The aim of this study was to describe a short, simple protocol for testing wall-mounted dispensers in hospitals.
In the first part of the study, dispensers in regular, daily clinical use were tested. Dispensed amount of handrub was collected after 10 minutes resting, and volume was measured. A total of 21 dispensers were tested, representing 5 different models from various manufacturers. In the second part, dispensers were investigated in laboratory environment. Samples were collected after 2, 3, 5, 10, 30 and 60 minutes. Every time point was measured in triplicates.
We found that even the same type of dispensers can perform differently. From one particular type of dispenser, 5 pieces were tested; in the worst case, after 10 minutes resting idle the dispensed amount decreased to 58% of the original volume, while other pieces of the same type did not lose volume (0% and 2%). During the second part, dispensers were defined as defective if dispensed volume decreased by more than 40% during an hour. In the case of defective dispensers, a significant decrease is detectable even after 3 minutes.
Results suggest that all dispensers should be quality checked regularly, as even the same type dispensers can perform fundamentally different in their critical function of dispensing the proper amount. In the case of defective dispensers, there is no need for time-consuming long-term assessment measurements, as the decrease can be detected in minutes.

Additional Information

Sz. Bansaghi is supported by the ÚNKP-19-19-3-I-SE-102 New National Excellence Program of the Ministry for Innovation and Technology.

Bemutatás módja

Szóbeli

Kind

Szabad

Status

elfogadva

Accepted presentation method

poszter

Előadás fájl jóváhagyás

nem rendelkezett róla

Előadó

4690

Start

11:20

End

11:23

Authors (legacy)

Szava Bansaghi1, Nora Balazsi2, Akos Lehotsky3, Istvan Barcs4, Tamas Haidegger5
1 School of PhD studies, Semmelweis University, Budapest, Hungary
2 Korányi National Institute of Pulmonology, Budapest, Hungary
3 National Institute of Oncology, Budapest, Hungary
4 Department of Epidemiology, Semmelweis University, Budapest, Hungary
5 University Research and Innovation Center, Obuda University, Budapest, Hungary