Poster Session III. - V: Cardiovascular Medicine and Research
Dr. Orbán Gábor
MXHUTJ
Heart and Vascular Center, Semmelweis University
+36304905897
gabor.orban.dr@gmail.com
Comparison of room times between pulsed-field ablation and very high-power short-duration ablation
Gábor Orbán1, Márton Boga1, Zoltán Salló1, István Osztheimer1, Klaudia Vivien Nagy1, Péter Perge1, Edit Tanai1, Ferenc Komlósi1, Patrik Tóth1, Béla Merkely1, László Gellér1, Nándor Szeged1
1: Heart and Vascular Center, Semmelweis University
Poszter
Poster Session III. - V: Cardiovascular Medicine and Research
Hungarian
Cardiovascular Medicine and Research
Introduction: Pulsed-field ablation (PFA) has shown promise in improving atrial fibrillation (AF) ablation efficiency by reducing skin-to-skin procedure times while maintaining safety compared to advanced radiofrequency (RF) methods such as very high-power short-duration (vHPSD) ablation. While PFA requires deeper sedation, its effect on the total time spent in the operating room (OR) is unknown.
Aims: We aimed to compare the room time (i.e., the time between the patient entering and leaving the OR) and procedural subsections’ times of PFA and vHPSD procedures.
Method: We enrolled consecutive patients who underwent PFA or vHPSD ablation at our center between November 2023 and July 2024. Room and procedural subsections’ times were analyzed and compared. Operators were divided into two subgroups by completed AF cases: experienced (300-1000 cases) and expert (>1000 cases) physicians.
Results: We included 131 patients [66 (55-71) years, 86 (65.6%) had paroxysmal AF]. Eighty-seven (66%) patients underwent PFA, and 44 (34%) underwent vHPSD ablation. Twenty-four patients (27.6%) underwent additional ablation beyond PVI in the PFA group, while none had additional ablation with vHPSD. PFA outperformed vHPSD in terms of room time [71 (64-80) vs. 88 (75-99.8) mins, p<0.001]. Furthermore, almost all procedural phases were significantly shorter in PFA procedures compared to vHPSD (all p<0.001), except the "door-in to puncture" and the "puncture to transseptal" time (both p>0.05). Meanwhile, the "sheath-out to door-out" time was significantly longer in PFA cases (p<0.001). Expert operators’ room times were shorter than experienced ones’ with both energy sources. However, the difference was clinically less meaningful with PFA than with vHPSD [PFA: 69 (60.3-74) vs. 76 (66-87.3) mins, and 80 (72-87) vs. vHPSD: 97.5 (88.8-114.5) mins, respectively, both p<0.001]. One major non-fatal complication occurred with PFA, while no major complications occurred with vHPSD.
Conclusion: PFA results in significantly shorter room time in AF ablation than vHPSD. The room time of PFA is less dependent on operator experience. PFA may enhance time efficiency in the EP lab, even compared to the fastest RF technology.
Funding: EKÖP-2024-265; MD-PhD Excellence Program: EFOP-3.6.3-VEKOP-16-2017-00009; Gedeon Richter Excellence PhD Scholarship of Gedeon Richter; Kerpel Scholarship 2024
Semmelweis University
Dr. Nándor Szegedi
I give consent to the publication of my abstract on the website of the congress.
in doctoral studies after complex exam (PhD)
Szabad
elfogadva
poszter
nem rendelkezett róla
6860
14:48
14:54